Basic Info.
Model NO.
FGGDJ-JSYL-YLS-12A/YLS-12B-A
After-sales Service
Online Technical Support
Application
Laboratory Apparatus
Light Number
Monochromator
Certification
ISO9001, CE
Product Model
Fggdj-Jsyl-Yls-12A/Yls-12b-a
Swinging Frequency (Times/Min.)
33/40± 2
Transport Package
Wooden Box
Specification
600*470*220mm
Product Description
Product Description
Product Introduction
Adopted the modern transducer technology, the Smart Weighing Instrument for Blood Collection (hereafter abbreviated as Weighing Instrument) consists of parts such as tray, vibration unit and single-chip control circuit etc. Due to its' scientific structure and long performance life, it can meet the users' demands of high efficiency, accuracy, consecutiveness and automatic. Meanwhile it can avoid artificial error effectively and physical damages to the blood to ensure livability of the active ingredients in the blood. It can better meet with the requirements of legal measuring management and procedure control of blood collection. So it is a right choice for any blood collection organizations at anyplace.
Instrument Operation:
1.Preparations
Open the package and take out all the parts to check if they are all in readiness. Install the tray. Connect with the power cable.
2.Turning on the instrument
Switch to "-" position and the instrument turns into self-check procedure with bumming sounds and after that it indicates "X 0".(X refers to the selected gear value)
3. Zero Adjustment and Tare
Push "Tare/Calibration" to realize manual zeroing,which is also applicable to tare operation.
4.Calibration (Take shift 2 as an example)
(1) Select shift "2" and zero by pushing "Tare/Calibration" button.
(2) Push the "Tare/Calibration" button for 3 seconds and the instrument start tooting. After
two times short tootings and one time long tooting, release the button and it indicates "str".
(3) Put on a 200ml weight and push the "Tare/Calibration" button for 3 seconds. The
instrument starts automatic calibration till it indicates "end" "200" and alarms simultaneously.
(4) Take out the weight for finishing the calibration and return to normal weighing display.
5.Shift Selection
Push the "Choose/Unit" button to start reciprocal selections from 0-9 and select the expected shift by releasing the button.
6.Self-set Blood Collection Weight
(1) Select the shift "5" ( can be set for 5-9 shifts) , Press "Set/ Enter" key
(2) Input the preset value by pushing the buttons of "unit digit", "tens digit" and "hundreds'digit"
(3) The machine is ready for weighing after pushing the "Set/ Enter" button.
7.Swinging Setting
The operation mode is selectable by pushing the "Sway/Hundred" button.
Display lamp on--- swinging;Display lamp off---
swinging stop(ex-work set is under this mode)
8.Alarm
Display lamp on- sound and light alarm (ex-work set is under this mode)
Display lamp off- only light alarm
Push "Cancel/Ten" button to remove all the alarm.
9. Power off
Turn off the switch on the rear of the machine after the work finished and cut off the
power supply.
Product Parameters
Type Specification | YLS-12A | YLS-12B |
Working Condition | -10-40ºC,Relative Humidity Less than 85% |
Power Supply | AC220V,50/60Hz,12VA | AC220V,50/60Hz,40VA |
Fuses | F1AL250V, Ø5×20mm |
Options (ml) | Shift 0 | No maximum weight |
Shift 1 | 0~100 |
Shift 2 | 0~200 |
Shift 3 | 0~300 |
Shift 4 | 0~400 |
Shifts 5~9 | Self-set Weight | Self-set Weight |
Division Value(mL) | 1 |
Hydrometry (g/mL) | 1.05 |
Swinging Angle | 13± 2° |
Swinging Frequency (times/min.) | 33/40± 2 |
Tolerance | ±2% |
Alarm and Stop | Sound and Light Alarm | Alarm and Stop |
Suitable Stop Tube | -- | Outside diameter: Ø3~Ø6mm |
Stop Thrust (N) | -- | ≮14 |
Outside Dimension(mm) | 218×165×160 | 275×230×210 |
Weight (kg) | 2.6 | 4.2 |
Related Products
Latest News
Company Profile
FAQ
1.Why choose BIOMETER?
We are a good manufactuer and reliable trading company in lab furniture and lab equipment, Offer OEM & ODM service.
2.How about the sample of our product?
We could send you the samples but the freight and the sample are charged.
3.How about Biometer payment term?
T/T & L/C &Western Union etc(40% deposit, the balance before shipment).
4.How about delivery time?
Within 7-15 workdays after receiving deposit.
5.What is the shipping port?
FOB to Qingdao Port,China(Also can ship according to customers' requests).
6.How about the package?
Bubble film + Cotton +Standard export wooden case.
7.How to inspect the goods?
Products will be checked by our QC staff frist, then our project manager.
Client can come and check by themselves or third partycheck is available.
Address:
Room 709, Building 6, No. 506, Huicheng Road, Chengyang Street, Chengyang District, Qingdao, Shandong
Business Type:
Trading Company
Business Range:
Chemicals, Furniture, Health & Medicine, Industrial Equipment & Components, Tools & Hardware
Company Introduction:
Established in 2011, Biometer Co., Ltd. Has been focusing on one-stop-shop solutions for research, development and marketing of medical equipment and laboratory equipment products for various fields covering government departments, scientific research institutions, colleges, biomedicine, advanced material, chemical industry, environment, food, electronics and electrical appliances, etc. For more than 10 years.
Our Products including laboratory equipment, sterilizer and disinfection equipment, laboratory safety protection product, cold chain product, medical equipment, general analytical equipment, measuring equipment, physical test equipment etc. A variety of our products have been granted with EU, CE, EN, FDA and other authoritative certificates. Until now, we have set foot in Philippines, Namibia, Ethiopia, Brazil, India, Spain and etc.
Biometer has a large team of professionals international trading team. With excellent research team, strong quality control team, professional sales team and responsible after-sale service team, support online technical survice etc
Biometer will always uphold the people-oriented goal, To create a better future on the international stage